banner

News

Apr 10, 2023

Process and Control Today

18/01/2023 Cowan Dynamics Inc.

For over 65 years, Cowan Dynamics has continued leading the way with our innovative valve automation solutions. Our SIL-3 Capable products are used globally in harsh environments and are chosen for their safety features, product performance, and reliability. For this reason, all our products go through a SIL analysis and certification process, this is no different for our newest addition the E2H-ESD, which has recently been SIL-3 Certified.

The E2H-ESD is an electro-hydraulic actuator that has been designed to operate emergency shutdown valves (ESDV). As part of the SIL certification process, cycle testing of the unit was done to determine if, and when, a component may fail, to ensure repeatable and reliable operation of the unit, and to quantify the temperature rise of the different components which will dictate the duty cycle of the equipment for the specific ambient temperature range of the operating environment. This test is expected to complete a minimum of 20,000 cycles, when completed it extended to over 26,000 total.

In addition, stand-by testing was performed. ‘Standby time’ is the time that the unit can stay in the ‘Reset’ position before the hydraulic pump needs to be started to recharge. This time for the ESD valve is crucial because the valve will remain in the ‘reset’ position for a long period of time. A system that is not capable of staying in the ‘reset’ position for a long time will result in a high energy consumption system. Once our test was completed it concluded that the system could maintain the valve in its ‘reset’ position for over a month without the need of starting the hydraulic pump to recharge.

To ensure the reliability of the actuator under service, a load test was also performed to provide more data for the SIL calculation. This article provides details on the importance of SIL certification to ensure safety and reliability.

Each SIL is represented in the following table with its associated Average Probability of Failure on Demand (PFDAvg) and Average Risk Reduction Factors (RRFAvg).

SIL

PFDAvg

RRFAvg

SIL 1

0.1 – 0.01

10 – 100

SIL 2

0.01 – 0.001

100 – 1000

SIL 3

0.001 – 0.0001

1000 – 10000

SIL 4

0.0001 – 0.00001

10000 – 100000

In accordance with the IEC 61508, SIL 3 is one of the highest levels of safety integrity. An average risk reduction factor of 1.000 - 10.000 is applied to failures on demand, and 10-8 - 10-7 is applied to failures per hour.

What is SIL?

A Safety Integrity Level (SIL) is a method for analyzing and qualifying the requirements for safety instrumented systems. In simple terms, SIL is the level of redundancy of risk-reduction provided by a safety function of how many steps or safety devices do I have in my system that prevent the system from malfunctioning?

To help operators quantify the safety performance requirements for hazardous operations, the International Electrotechnical Commission (IEC) introduced the following industry standards:

IEC 61508: 2010 Functional safety of electrical/electronic/ programmable electronic safety-related systems

In the hydrocarbon and oil and gas industries, these standards have been widely adopted to define Safety Instrumented Systems and their reliability to improve safety and availability.

How are actuators certified as "suitable for use" for specific SIL ratings?

There are two aspects to the process of attaining a SIL certificate. The first step involves assessing the design and failure rates of the equipment.

Attaining a SIL certificate can be accomplished through either of two techniques: FMEDA (Failure Modes, Effect, and Diagnostic Analysis) and "Proven in Use."

The second aspect is an audit of the vendor's manufacturing and quality processes. As a result of this audit, the vendor proves its capability to manufacture the product to the designed performance standard. These assessments must be conducted by an accredited accreditation body, such as Exida (Cowan Dynamics SIL products are certified by Exida) or TÜV

In conclusion, SIL is both a target and a challenge, and achieving it requires an organization and individual to employ the best skills and knowledge available. Technology and human behavior must be aligned when determining the need for SIL: Safety Integrity Level.

SIL represents a new frontier in risk reduction by achieving safety as "freedom from unacceptable risk of harm."

Print this article

For more information, please contact:Maria AguirreCowan Dynamics Inc.6194 rue Notre-Dame OuestMontrealQuebec H4C 1V4Tel: +1-587-487-6523Email: [email protected]: www.cowandynamic.com

Visit company profile page

When and how to use closed loop speed control for DC motors

Login or Register

Process and Control Today are not responsible for the content of submitted or externally produced articles and images. Click here to email us about any errors or omissions contained within this article.

This article provides details on the importance of SIL certification to ensure safety and reliability. SIL PFDAvg RRFAvg SIL 1 0.1 – 0.01 10 – 100 SIL 2 0.01 – 0.001 100 – 1000 SIL 3 0.001 – 0.0001 1000 – 10000 SIL 4 What is SIL? How are actuators certified as "suitable for use" for specific SIL ratings? For more information, please contact: Visit company profile page
SHARE